Talk:Electric power transmission/Archive 2

Page contents not supported in other languages.
From Wikipedia, the free encyclopedia
Archive 1 Archive 2

Overhead Transmission section, clarification required

In the 'Overhead Transmission' section of the article, there is a line that says "For normal AC lines thicker wires would lead to a relatively small increase in capacity due to the skin effect (which causes most of the current to flow close to the surface of the wire)." ----- The person that wrote this must explain what they mean by thicker wires would lead to a relatively small increase in capacity due to the skin effect. Why would skin effect increase the capacity? This needs to be properly explained, as it doesn't make sense at this moment. KorgBoy (talk) 23:22, 7 April 2020 (UTC)

From what I understand, it means that current would grow more linearly (proportional to cross sectional circumference) while weight and cost would grow quadratically (proportional to the cross sectional area). So at some point it's not worth it to increase the cross section of wires. --Ita140188 (talk) 04:35, 8 April 2020 (UTC)

Section merging

Would it be better if System and Bulk power transmission be merged? Overhead transmission and Underground transmission can also be part of this new section. For the control section, it misses the loadflow analysis and the busbar voltage control for the transmission network. Planning to do an overhaul base on the said changes, any comments?JC1 (talk) 11:38, 5 August 2020 (UTC)

Tesla Polyphase System

Per this edit: most of the changes are incorrect. The Westinghouse system was called the "Tesla Polyphase System" [1]. Also do not arbitrarily change file names, it breaks the link. If a point needs to be made about Tesla's system being two-phase, please make it in the body of the article with the appropriate references. Fountains of Bryn Mawr (talk) 15:42, 22 June 2021 (UTC)

Longest power line?

"Records" has:

Longest power line: Inga-Shaba (Democratic Republic of Congo) (length: 1,700 kilometres or 1,056 miles)

However:

Name (Chinese) 	Type 	Voltage (kV) 	Length (km) 	Power rating (GW) 	Year Completed 
Zhundong–Wannan(准东-皖南) 	HVDC 	±1100 	3324 	12 	September 2019

https://en.wikipedia.org/wiki/Ultra-high-voltage_electricity_transmission_in_China

200.68.169.47 (talk) 02:15, 13 October 2021 (UTC) baden k.

Split of superconducting cables

  • Support but the new page will need updated references Gusfriend (talk) 01:51, 26 January 2022 (UTC)
  • Oppose - it's one paragraph and still pretty much at the "sunday supplement, whiz-bang world of the futrure" stage of development. Untag stale tag for now. --Wtshymanski (talk) 04:13, 5 February 2022 (UTC)

Redundant Units

I haven't edited anything myself as I don't know if this is standard notation in engineering circles, but all the unit notation in the "Modeling and the transmission matrix" is redundant. Nebulo9 (talk) 10:14, 2 May 2022 (UTC)