Membranes

A membrane is a selective barrier that allows the passage of certain constituents and retains other constituents found in the liquid [1] . The influent of a membrane is known as the feed-stream, the liquid that passes through the membrane is known as the permeate and the liquid containing the retained constituents is the retentate or concentrate. The degree of selectivity depends on the membrane pore size. Depending on the pore size of membranes, they can be classified as microfiltration (MF), ultrafiltration (UF), nanofiltration (NF) and reverse osmosis (RO) membranes.

Membrane Processes Classification[edit]

Microfiltration (MF)[edit]

Microfiltration removes particles higher than 0,08-2 µm and operates within a range of 7-100 kPa [2]. Microfiltration is used to remove residual suspended solids (SS), to remove bacteria in order to condition the water for effective disinfection and as a pre-treatment step for reverse osmosis. Relatively recent developments are membrane bioreactors (MBR) which combine microfiltration and a bioreactor for biological treatment.

Ultrafiltration (UF)[edit]

Ultrafiltration removes particles higher than 0,005-2 µm and operates within a range of 70-700kPa [3]. Ultrafiltration is used for many of the same applications as microfiltration. Some ultrafiltration membranes have also been used to remove dissolved compounds with high molecular weight, such as proteins and carbohydrates. In addition, they are able to remove viruses and some endotoxins.

Nanofiltration (NF)[edit]

Nanofiltration is also known as “loose” RO and can reject particles smaller than 0,001 µm. Nanofiltration is used for the removal of selected dissolved constituents from wastewater. NF is primarily developed as a membrane softening process which offers an alternative to chemical softening.

Likewise, nanofiltration can be used as a pre-treatment before directed reverse osmosis. The main objectives of NF pre-treatment are[4]: (1). minimize particulate and microbial fouling of the RO membranes by removal of turbidity and bacteria, (2) prevent scaling by removal of the hardness ions, (3) lower the operating pressure of the RO process by reducing the feed-water total dissolved solids (TDS) concentration.

Reverse Osmosis (RO)[edit]

Reverse Osmosis is commonly used for desalination. As well, RO is commonly used for the removal of dissolved constituents from wastewater remaining after advanced treatment with microfiltration. RO excludes ions but it requires high pressures to produce deionizer water (850-7000 kPa).

Membrane Configurations[edit]

In the membrane field, the term module is used to describe a complete unit comprised of the membranes, the pressure support structure, the feed inlet, the outlet permeate and retentate streams, and an overall support structure. The principal types of membrane modules are:

  • Tubular, where membranes are placed inside a support porous tubes, and these tubes are placed together in a cylindrical shell to form the unit module. Tubular devices are primarily used in micro and ultra filtration applications because of their ability to handle process streams with high solids and high viscosity properties, as well as for their relative ease of cleaning.
  • Hollow fiber, consists of a bundle of hundreds to thousands of hollow fibers. The entire assembly is inserted into a pressure vessel. The feed can be applied to the inside of the fiber (inside-out flow) or the outside of the fiber (outside-in flow).
  • Spiral Wound, where a flexible permeate spacer is placed between two flat membranes sheet. A flexible feed spacer is added and the flat sheets are rolled into a circular configuration.
  • Plate and frame consist of a comprised of a series of flat membrane sheets and support plates. The water to be treated passes between the membranes of two adjacent membrane assemblies. The plate supports the membranes and provides a channel for the permeate to flow out of the unit module.

Membrane process operation[edit]

The key elements of any membrane process relate to the influence of the following parameters on the overall permeate flux are:

  • The membrane permeability (k)
  • The operational driving force per unit membrane area (Trans Membrane Pressure, TMP)
  • The fouling and subsequent cleaning of the membrane surface.
Flux, pressure, permeability[edit]

The total permeate flow from a membrane system is given by following equation:

Where Qp is the permeate stream flowrate [kg·s-1], Fw is the water flux rate [kg·m-2·s-1] and A is the membrane area [m2]


The permeability (k) [m·s-2·bar-1] of a membrane is given by the next equation:



The transmembrane pressure (TMP) is given by the following expression:



where PTMP is the Transmembrane Pressure [kPa], Pf the inlet pressure of feed streem [kPa]; Pc the pressure of concentrate strem [kPa]; Pp the pressure if permeate stream [kPa].

The rejection (r) could be defined as the amount of particles that have been removed from the feedwater.

The corresponding mass balance equations are:




In order to control the operation of a membrane process, two modes, with respect to the flux and to the TMP (Trans Membrane Pressure), can be used. These modes are: (1) constant TMP and (2) constant flux.

The operation modes will be affected when the rejected materials and particles in the retentate tend to accumulate in the membrane. At a given TMP, the flux of water through the membrane will decrease and at a given flux, the TMP will increase, reducing the permeability (k). This phenomenon is known as fouling, and it is the main limitation to membrane process operation.


Constant TMP and constant Flux operations
Dead-end and cross-flow operation modes[edit]

Two operation modes for membranes can be used. These modes are:

  • Dead end filtration where all the feed applied to the membrane passes through it, obtaining a permeate. Since there is no concentrate stream, all the particles are retained in the membrane. Raw feed-water is sometimes used to flush the accumulated material from the membrane surface [5].


  • Cross-flow filtration where the feed water is pumped with a cross flow tangential to the membrane and a concentrate and permeate streams are obtained. This model implies that for a flow of feed-water across the membrane, only a fraction is converted to permeate product. This parameter is termed “conversion” or “recovery” (S). The recovery will be reduced if the permeate is further used for maintaining processes operation, usually for membrane cleaning.


Schematic process of dead-end and cross-flow filtration


Filtration leads to an increase of the resistance against the flow. In the case of dead-end filtration process, the resistance increases according to the thickness of the cake formed on the membrane. As a consequence, the permeability (k) and the flux rapidly decrease, proportionally to the solids concentration[1] and, thus, requiring a periodic cleaning.

For cross-flow processes, the deposition of material will continue until the forces of the binding cake to the membrane will be balanced by the forces of the fluid. At this point, cross-flow filtration will reach a steady-state condition[2], and thus, the flux will remain constant with time. Therefore, this configuration will demand less periodic cleaning.

Fouling[edit]

Fouling can be defined as the potential deposition and accumulation of constituents in the feed stream on the membrane .

Fouling can take place through a number of physicochemical and biological mechanisms which are relate to the increase deposition of solid material onto the membrane surface. The main mechanisms by which fouling can occur, are:

  • Build-up of constituents of the feedwater on the membrane which causes a resistance to flow. This build-up can be divided into different types:
Pore narrowing, which consists of solid material that it has been attached to the interior surface of the pores.
Pore blocking occurs when the particles of the feed-water become stuck in the pores of the membrane.
Gel/cake layer formation takes places when the solid matter in the feed is larger than the pore sizes of the membrane.
  • Formation of chemical precipitates known as scaling
  • Colonization of the membrane or biofouling takes place when microorganisms grow on the membrane surface.
Fouling control and mitigation[edit]

Since fouling is an important consideration in the design and operation of membrane systems, as it affects pre-treatment needs, cleaning requirements, operating conditions, cost and performance, it should prevented, and if necessary, removed. Optimizing the operation conditions is important to prevent fouling. However, if fouling have already take place, it should be removed by using physical or chemical cleaning.


Physical cleaning techniques for membrane include membrane relaxation and membrane backwashing.

  • Back-washing or back-flushing consist of pumping the permeate in the reverse direction through the membrane. Back-washing removes successfully most of the reversible fouling caused by pore blocking. Backwashing can also be enhanced by flushing air through the membrane [6] . Backwashing increase the operating costs since energy is required to achieve a pressure suitable for permeate flow reversion.
  • Membrane relaxation consists of pausing the filtration during a period of time, and thus, there is no need for permeate flow reversion. Relaxation allows filtration to be maintained for longer period of time before the chemical cleaning of the membrane.
Recent studies have assessed to combine relaxation and backwashing for optimum results [7],[8].

Chemical cleaning. Relaxation and backwashing effectiveness will decrease with operation time as more irreversible fouling accumulates on the membrane surface. Therefore, besides the physical cleaning, chemical cleaning may also be recommended. They include:

  • Chemical enhanced backwash, that is, a low concentration of chemical cleaning agent is added during the backwashing period.
  • Chemical cleaning, where the main cleaning agents are sodium hypochlorite (for organic fouling) and citric acid (for inorganic fouling). It should be point out, though, that every membrane supplier proposes their own chemical cleaning recipes, which differ mainly in terms of concentration and methods [9].


Optimizing the operation condition. Several mechanisms can be carried out to optimize the operation conditions of the membrane to prevent fouling, for instance:

  • Reducing flux. The flux always reduces fouling but obviously it impacts on capital cost since it demands more membrane area. It consists of working at sustainable flux which can be defined as the flux for which the TMP increases gradually at an acceptable rate, such that chemical cleaning is not necessary.
  • Using cross-flow filtration instead of dead-end. In cross-flow filtration only a thin layer is deposited on the membrane since not all the particles are retained on the membrane, but the concentrate removes them.
  • Pre-treatment of the feed water is used to reduce the suspended solids and bacterial content of the feed-water. Flocculants and coagulants are also used, like ferric chloride and aluminum sulfate that, once dissolved in the water, adsorbs materials such as suspended solids, colloids and soluble organic [10].

References[edit]

  1. ^ Cheryan, M (1998). Ultrafiltration and Microfiltration Handbook. Lancaster, PA.: echonomic Publishing Co., Inc.
  2. ^ Crites and Tchobangiglous (1998). Small and Decentralized Wastewater Management Systems. New York: McGraw-Hill Book Company.
  3. ^ Crites and Tchobangiglous (1998). Small and Decentralized Wastewater Management Systems. New York: McGraw-Hill Book Company.
  4. ^ Adam S, Cheng RC, Vuong DX, Wattier KL (2003). "Long Beach's dual-stage NF beats single-stage SWRO". Desalination Water Reuse. 13: 18-21.{{cite journal}}: CS1 maint: multiple names: authors list (link)
  5. ^ Metcalf and Eddy (2004) Wastewater Engineering, Treatment and Reuse, McGraw-Hill Book Company, New York. Fourth Edition.
  6. ^ Sun, Y (2004). "dual functional filtration/aeration membrane bioreactor for domestic wastewater treatment". Proceedings of Water Environment- Membrane Technology. {{cite journal}}: Unknown parameter |coauthors= ignored (|author= suggested) (help)
  7. ^ Vallero, M.V.G., Lettinga, G. and Lens, P.N.L (2005). "High rate sulfate reduction in a submerged anaerobic membrane bioreactor (sambar) at high salinity". Journal of Membrane Sciences. 253 (1–2): 217-232. doi:10.1016/j.memsci.2004.12.032.{{cite journal}}: CS1 maint: multiple names: authors list (link)
  8. ^ I.-J. Kang, C.-H. Lee, K.-J. Kim (2003). "Characteristics of microfiltration membranes in a membrane coupled sequencing batch reactor system". Water Res. 37 (5): 1192–1197. doi:10.1016/S0043-1354(02)00534-1. PMID 12553996.{{cite journal}}: CS1 maint: multiple names: authors list (link).
  9. ^ P. Le-Clech, A. Fane, G. Leslie, A (2005). "Childress, The operator's perspective". Filt. Sep. 42: 20-23. doi:10.1016/S0015-1882(05)70556-5.{{cite journal}}: CS1 maint: multiple names: authors list (link)
  10. ^ Pierre Le-Clech, Vicki Chen, Tony A.G. Fane (2006). "Fouling in membrane bioreactors used in wastewater treatment". Journal of Membrane Science. 284 (1–2): 17-53. doi:10.1016/j.memsci.2006.08.019.{{cite journal}}: CS1 maint: multiple names: authors list (link)

Bibliography[edit]

  • Metcalf and Eddy. Wastewater Engineering, Treatment and Reuse. McGraw-Hill Book Company, New York. Fourth Edition, 2004.
  • Paula van den Brink, Frank Vergeldt, Henk Van As, Arie Zwijnenburg, Hardy Temmink, Mark C.M.van Loosdrecht. "Potential of mechanical cleaning of membranes from a membrane bioreactor". Journal of membrane science. 429, 2013. 259-267.
  • Simon Judd. The Memrabne Bioreactor Book: Principles and Applications of Membrane Bioreactors for Water and Wastewater Treatment. Elsevier, 2010.

Category:Membranes Category:Fouling Category:Water technology Category:Water treatment